Construction workers safety
Containing launched rockfalls
Loose and weathered rock slope
Landslide Technology performed rock slope
hazard evaluation and mitigative design for the Corps of Engineers Intake Tower
reconstruction project at Cougar
Dam. A basic strategy
for preventing rockfall into the work areas below the
slope was developed at an initial site visit. Steep slopes and highly weathered loose rock
prevented removal of all the potential hazards. Highly
irregular slopes necessitated a complex design to
control rolling and bouncing rock. After extensive
rockfall modeling, a multifaceted plan was devised which
limited the potential of rockfall hazards through scaling, rock bolts, draped
mesh, and rockfall catchment barriers. Follow-up
visits were made to determine the effectiveness of
scaling and necessity for further remediation.
|